Bosch Appliances DVR DVR 440 دليل المستخدم

Digital Video Recorder 440/480 Series  
DVR 440 / DVR 480  
en Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Digital Video Recorder 440/480 Series  
Table of Contents | en  
3
Table of Contents  
Safety  
Safety precautions  
Important safety instructions  
Important Notices  
FCC and UL  
Bosch notices  
Introduction  
Digital video recorder applications  
Versions  
Manuals  
Features  
Unpacking  
Package contents  
Installation environment  
Mounting  
Ventilation  
Temperature  
قوة إمداد تموين  
Environment  
Associated equipment  
Warranty  
Quick install  
Connections  
Primary connections  
Optional connections  
Powering up  
First-time use  
Quick install menu  
International  
Continuous Recording  
Network  
Hardware setup  
Camera connections  
Audio connections  
Monitor connections  
VGA (Monitor A)  
CVBS  
RS-232 COM port connections  
Ethernet connection  
USB connectors  
RS485 port  
External alarm I/O connection  
Power supply  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
4
en | Table of Contents  
Maintenance  
Digital Video Recorder 440/480 Series  
Operating instructions  
Front panel controls  
Keys  
Indicators  
Mouse Controls  
Viewing pictures  
Monitor A  
Monitor B  
Viewing  
Live and playback  
Live mode  
Playback mode  
Overview of the menu system  
Access using the front panel keys  
Access using the mouse  
Main menu  
Search  
Date/time search  
Event search  
Smart search  
Export  
System information  
Log  
Triggers and alarms  
Alarm inputs  
Motion events  
Video loss alarm  
Multiple alarms  
Configuration menu  
Camera  
Camera  
Maximum frame rates DVR 440  
Maximum frame rates DVR 480  
Video adjustment  
PTZ  
Continuous Recording  
Input Recording  
Motion Recording  
Network Live Streaming  
Video format  
Schedule  
Schedule  
Display  
لغة  
Monitor A  
Monitor B  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Bosch Security Systems  
Digital Video Recorder 440/480 Series  
Table of Contents | en  
5
Event  
Input  
Motion  
Network  
6.5.2  
6.5.3  
TCP/IP  
Streaming to mobile devices  
Connecting using a smart mobile phone  
DDNS  
Notification  
Mail  
System  
Date/Time  
NTP  
Beeper  
Users  
Configuration  
Hard Disk  
System  
Web Client Software  
Getting started  
System requirements  
Connecting to the DVR 400 Series the first time  
How to log on  
Menu structure differences  
Introducing the browser window  
Live mode  
PTZ camera control  
Camera views  
Playback mode  
Export mode  
Configuration mode  
Archive Player  
Getting started  
System requirements  
Installation  
Starting the Program  
Introducing the main window  
Open button  
Camera Views  
Viewing Images  
Assigning Cameos  
Using the playback controls  
Capturing a still image  
Find image  
Video slider bar  
Checking authenticity  
Exit button  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
6
en | Table of Contents  
Digital Video Recorder 440/480 Series  
Menu default values  
Technical specifications  
Electrical  
Mechanical  
Environmental  
Electromagnetic and Safety  
USB memory sticks  
Appendix  
Software licenses  
Bosch software  
Other licenses — copyright notices  
Warranties and disclaimer of warranties  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Bosch Security Systems  
Digital Video Recorder 440/480 Series  
Safety | en  
7
1
Safety  
1.1  
Safety precautions  
DANGER!  
High risk: This symbol indicates an imminently hazardous situation such as "Dangerous  
Voltage" inside the product.  
If not avoided, this will result in an electrical shock, serious bodily injury, or death.  
WARNING!  
Medium risk: Indicates a potentially hazardous situation.  
If not avoided, this could result in minor or moderate bodily injury.  
CAUTION!  
Low risk: Indicates a potentially hazardous situation.  
if not avoided, this could result in property damage or risk of damage to the unit.  
1.2  
Important safety instructions  
Read, follow, and retain for future reference all of the following safety instructions. Heed all  
warnings on the unit and in the operating instructions before operating the unit.  
1. Cleaning - Unplug the unit from the outlet before cleaning. Follow any instructions  
provided with the unit. Generally, using a dry cloth for cleaning is sufficient but a moist,  
fluff-free cloth or leather shammy may also be used. Do not use liquid cleaners or aerosol  
cleaners.  
2. Heat Sources - Do not install the unit near any heat sources such as radiators, heaters,  
stoves, or other equipment (including amplifiers) that produce heat.  
3. Ventilation - Any openings in the unit enclosure are provided for ventilation to prevent  
overheating and ensure reliable operation. Do not block or cover these openings. Do not  
place the unit in an enclosure unless proper ventilation is provided, or the manufacturer's  
instructions have been adhered to.  
4. Water - Do not use this unit near water, for example near a bathtub, washbowl, sink,  
laundry basket, in a damp or wet basement, near a swimming pool, in an outdoor  
installation, or in any area classified as a wet location. To reduce the risk of fire or  
electrical shock, do not expose this unit to rain or moisture.  
5. Object and liquid entry - Never push objects of any kind into this unit through openings  
as they may touch dangerous voltage points or short-out parts that could result in a fire  
or electrical shock. Never spill liquid of any kind on the unit. Do not place objects filled  
with liquids, such as vases or cups, on the unit.  
6. Lightning - For added protection during a lightning storm, or when leaving this unit  
unattended and unused for long periods, unplug the unit from the wall outlet and  
disconnect the cable system. This will prevent damage to the unit from lightning and  
power line surges.  
7. Controls adjustment - Adjust only those controls specified in the operating instructions.  
Improper adjustment of other controls may cause damage to the unit. Use of controls or  
adjustments, or performance of procedures other than those specified, may result in  
hazardous radiation exposure.  
8. Overloading - Do not overload outlets and extension cords. This can cause fire or  
electrical shock.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
     
8
en | Safety  
Digital Video Recorder 440/480 Series  
9. Power supply cord and plug protection - Power supply cords should be routed so that  
they are not likely to be walked on or pinched by items placed upon or against them,  
playing particular attention to cords and plugs, convenience receptacles, and the point  
where they exit from the appliance.  
10. Power disconnect - Units have power supplied to the unit whenever the power cord is  
inserted into the power source. The power cord plug is the main power disconnect  
device for switching off the voltage for the unit.  
11. Power sources - Operate the unit only from the type of power source indicated on the  
label. Before proceeding, be sure to disconnect the power from the cable to be installed  
into the unit.  
12. Servicing - Do not attempt to service this unit yourself. Opening or removing covers may  
expose you to dangerous voltage or other hazards. Refer all servicing to qualified service  
personnel.  
13. Damage requiring service - Unplug the unit from the main AC power source and refer  
servicing to qualified service personnel when any damage to the equipment has  
occurred, such as:  
the power supply cord or plug is damaged;  
exposure to moisture, water, and/or inclement weather (rain, snow, etc.);  
liquid has been spilled in or on the equipment;  
an object has fallen into the unit;  
unit has been dropped or the unit cabinet is damaged;  
unit exhibits a distinct change in performance;  
unit does not operate normally when the user correctly follows the operating  
instructions.  
14. Replacement parts - Be sure the service technician uses replacement parts specified by  
the manufacturer, or that have the same characteristics as the original parts.  
Unauthorized substitutions could void the warranty and cause fire, electrical shock, or  
other hazards.  
15. Safety check - Safety checks should be performed upon completion of service or repairs  
to the unit to ensure proper operating condition.  
16. Installation - Install in accordance with the manufacturer's instructions and in  
accordance with applicable local codes.  
17. Attachments, changes or modifications - Only use attachments/accessories specified by  
the manufacturer. Any change or modification of the equipment, not expressly approved  
by Bosch, could void the warranty or, in the case of an authorization agreement, authority  
to operate the equipment.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Digital Video Recorder 440/480 Series  
Safety | en  
9
1.3  
Important Notices  
Accessories - Do not place this unit on an unstable stand, tripod, bracket, or mount. The unit  
may fall, causing serious injury and/or serious damage to the unit. Use only with the cart,  
stand, tripod, bracket, or table specified by the manufacturer. When a cart is used, use  
caution and care when moving the cart/apparatus combination to avoid injury from tip-over.  
Quick stops, excessive force, or uneven surfaces may cause the cart/unit combination to  
overturn. Mount the unit per the manufacturer's instructions.  
All-pole power switch - Incorporate an all-pole power switch, with a contact separation of at  
least 3 mm in each pole, into the electrical installation of the building.If it is needed to open  
the housing for servicing and/or other activities, use this all-pole switch as the main  
disconnect device for switching off the voltage to the unit.  
Battery replacement - For qualified service personnel only - A lithium battery is located  
inside the unit enclosure. To avoid danger of explosion, replace the battery as per  
instructions. Replace only with the same or equivalent type recommended by the  
manufacturer. Refer all servicing to qualified service personnel.  
Batteries must not be disposed of in household waste. Dispose of batteries only at suitable  
collection points and, in the case of lithium batteries, mask the poles.  
For further information refer to: http://www.boschsecurity.com/standards  
Coax grounding:  
Ground the cable system if connecting an outside cable system to the unit.  
Connect outdoor equipment to the unit's inputs only after this unit has had its grounding  
plug connected to a grounded outlet or its ground terminal is properly connected to a  
ground source.  
Disconnect the unit's input connectors from outdoor equipment before disconnecting  
the grounding plug or grounding terminal.  
Follow proper safety precautions such as grounding for any outdoor device connected to  
this unit.  
U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA No.70, provides  
information regarding proper grounding of the mount and supporting structure, grounding of  
the coax to a discharge unit, size of grounding conductors, location of discharge unit,  
connection to grounding electrodes, and requirements for the grounding electrode.  
Disposal - Your Bosch product was developed and manufactured with high-quality material  
and components that can be recycled and reused. This symbol means that electronic and  
electrical appliances, which have reached the end of their working life, must be collected and  
disposed of separately from household waste material. Separate collecting systems are  
usually in place for disused electronic and electrical products. Please dispose of these units  
at an environmentally compatible recycling facility, per European Directive 2002/96/EC.  
Electronic Surveillance - This device is intended for the use in public areas only. U.S. federal  
law strictly prohibits surreptitious recording of oral communications.  
Electrostatic-sensitive device - Use proper CMOS/MOS-FET handling precautions to avoid  
electrostatic discharge. Wear required grounded wrist straps and observe proper ESD safety  
precautions when handling the electrostatic-sensitive printed circuit boards.  
Environmental statement - Bosch has a strong commitment towards the environment. This  
unit has been designed to respect the environment as much as possible.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
10 en | Safety  
Digital Video Recorder 440/480 Series  
Fuse rating - For protection of the device, the branch circuit protection must be secured with  
a maximum fuse rating of 16A. This must be in accordance with NEC800 (CEC Section 60).  
Grounding and polarization - This unit may be equipped with a polarized alternating current  
line plug (a plug with one blade wider than the other blade). This safety feature allows the  
plug to fit into the power outlet in only one way. If unable to insert the plug fully into the  
outlet, contact a locally certified electrician to replace the obsolete outlet. Do not defeat the  
safety purpose of the polarized plug.  
Alternately, this unit may be equipped with a 3-pole grounding plug (a plug with a third pin for  
earth grounding). This safety feature allows the plug to fit into a grounded power outlet only.  
If unable to insert the plug into the outlet, contact a locally certified electrician to replace the  
obsolete outlet. Do not defeat the safety purpose of the grounding plug.  
Moving - Disconnect the power before moving the unit. Move the unit with care. Excessive  
force or shock may damage the unit and the hard disk drives.  
Permanently connected equipment - Incorporate a readily accessible disconnect device  
external to the equipment.  
Pluggable equipment - Install the socket outlet near the equipment so it is easily accessible.  
Rack-mount  
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the  
operating ambient temperature of the rack environment may be greater than room  
ambient. Therefore, consideration should be given to installing the equipment in an  
environment compatible with the maximum ambient temperature (Tma) specified by the  
manufacturer.  
Reduced Air Flow - Installation of the equipment in a rack should be such that the amount  
of air flow required for safe operation of the equipment is not compromised.  
Mechanical loading - Mounting of the equipment in the rack should be such that a  
hazardous condition is not achieved due to uneven mechanical loading.  
Circuit Overloading - Consideration should be given to the connection of the equipment  
to the supply circuit and the effect that overloading of the circuits might have on  
overcurrent protection and supply wiring. Appropriate consideration of equipment  
nameplate ratings should be used when addressing this concern.  
Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.  
Particular attention should be given to supply connections other than direct connections  
to the branch circuit (e.g. use of power strips).  
SELV - All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits  
should only be connected to other SELV circuits.  
Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security  
Systems cannot be held liable for any damage that results from missing video information. To  
minimize the risk of lost digital information, Bosch Security Systems recommends multiple,  
redundant recording systems, and a procedure to back up all analog and digital information.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Digital Video Recorder 440/480 Series  
Safety | en  
11  
1.4  
FCC and UL  
FCC Information  
(U.S.A. and Canadian Models Only)  
This equipment has been tested and found to comply with the limits for a Class B digital  
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable  
protection against harmful interference in a residential installation. This equipment  
generates, uses, and can radiate radio frequency energy and, if not installed and used in  
accordance with the instructions, may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a particular installation. If  
this equipment does cause harmful interference to radio or television reception, which can be  
determined by turning the equipment off and on, the user is encouraged to try to correct the  
interference by one or more of the following measures:  
reorient or relocate the receiving antenna;  
increase the separation between the equipment and receiver;  
connect the equipment into an outlet on a circuit different from that to which the  
receiver is connected;  
consult the dealer or an experienced radio/TV technician for help.  
Intentional or unintentional modifications, not expressly approved by the party responsible  
for compliance, shall not be made. Any such modifications could void the user's authority to  
operate the equipment. If necessary, the user should consult the dealer or an experienced  
radio/television technician for corrective action.  
The user may find the following booklet, prepared by the Federal Communications  
Commission, helpful: How to Identify and Resolve Radio-TV Interference Problems. This booklet  
is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-  
000-00345-4.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
12 en | Safety  
Digital Video Recorder 440/480 Series  
1.5  
Bosch notices  
Copyright  
This manual is the intellectual property of Bosch Security Systems and is protected by  
copyright.  
All rights reserved.  
Trademarks  
All hardware and software product names used in this document are likely to be registered  
trademarks and must be treated accordingly.  
Note:  
This manual has been compiled with great care and the information it contains has been  
thoroughly verified. The text was complete and correct at the time of printing. The ongoing  
development of the products may mean that the content of the user guide can change without  
notice. Bosch Security Systems accepts no liability for damage resulting directly or indirectly  
from faults, incompleteness or discrepancies between the user guide and the product  
described.  
More information  
For additional information, please contact the nearest Bosch Security Systems location or  
visit our web site at:  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Introduction | en  
13  
2
Introduction  
2.1  
Digital video recorder applications  
The Digital Video Recorder 440/480 Series is a video and audio recording system that records  
multiple camera and audio signals while simultaneously providing live multiscreen viewing and  
playback. The unit has comprehensive search and playback facilities for viewing stored video.  
Once configured, all recording takes place in the background without requiring operator  
intervention.  
Maximum recording rates for CIF resolution of 30 (NTSC) and 25 (PAL) images per second  
(IPS), per channel, are guaranteed. By using only 4 channels you can record 2CIF in real time  
(30/25 IPS). Recording at 4CIF is also possible by lowering the IPS setting. The recording rate  
and quality are selectable per camera. An internal hard disk provides various storage  
capacities for recording.  
All models have extensive alarm handling functions and telemetry control. Alarm functions  
include motion detection in user-definable areas of the image on any camera input.  
The unit can be easily operated and programmed via the front panel control keys, mouse, and  
the on-screen display menu system. Two monitor outputs provide full-screen, multiscreen,  
and sequenced viewing.  
The video inputs, audio input and output, and alarm inputs and output are on the rear panel. A  
VGA connector provides output for an A monitor. A CVBS video output in either NTSC or PAL  
is also provided for Monitor B. Monitor A displays full-screen or quad digital pictures that can  
be frozen and zoomed. Monitor B displays live full-screen pictures.  
Use the Web application via a network for live viewing, playback, and configuration. Four  
simultaneous users can control the DVR 400 Series. The DVR 400 Series includes an  
authenticity check for both local and remote playback. A dedicated PC player is provided for  
playback of secure video files.  
2.1.1  
2.1.2  
Versions  
The DVR 440 Series models have 4 video channels and 4 alarm inputs; the DVR 480 Series  
models have 8 video channels and 4 alarm inputs. Both versions operate in a similar manner.  
The illustrations in this manual show the 4-channel version. The 8-channel version has 4  
additional video channels and 4 additional alarm inputs.  
Manuals  
This manual contains information about:  
Quick Installation - a brief overview on how to set up and install the product.  
Hardware Setup - a detailed description for installers on how to install the product.  
Operation - a detailed description for end-users on how to operate the unit.  
Web Control and Archive Player - a detailed description for end-users and administrators  
on how to set up and operate the Web Control and Archive Player software.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
       
14 en | Introduction  
Digital Video Recorder 440/480 Series  
2.1.3  
Features  
The DVR 440/480 Series has the following features:  
4/8 camera inputs  
1 audio input and 1 audio output  
Simultaneous recording and playback  
H.264 compression  
10/100Base-T Ethernet port for Ethernet connection and networking  
RS485 and RS232 serial port for data communication  
VGA monitor output (Monitor A)  
Full-screen and multiscreen display capabilities in live and playback modes  
CVBS monitor output (Monitor B)  
Full-screen in live with sequence  
Motion detection  
4/8 switching (alarm) inputs and 1 alarm output  
Video loss detection  
Audible alarm  
Pan, tilt, and zoom camera control via RS485/RS232  
Local archiving via USB  
E-mail notification with 10-second video clip on alarm  
Bosch DVR viewer App for live and PTZ control  
2.2  
Unpacking  
Inspect the package for visible damage. If any items appear to have been damaged during  
transport, notify the shipping company. Unpack carefully. This is electronic equipment and  
should be handled with care to prevent damage to the unit. Do not attempt to use the unit if  
any components are damaged. If any items are missing, notify your customer service  
representative or Bosch Security Systems sales representative. The shipping carton is the  
safest container in which to transport the unit. Save it and all packing materials for future use.  
If the unit must be returned, use the original packing materials.  
2.2.1  
Package contents  
Check for the following items:  
Digital Video Recorder (DVR 440/480 Series unit)  
Operation manual (this manual)  
Power supply cords/power adapter  
Terminal blocks for external I/O connectors  
CD-ROM containing the software and documentation  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
     
Digital Video Recorder 440/480 Series  
Introduction | en  
15  
2.3  
Installation environment  
2.3.1  
Mounting  
The DVR 440/480 Series is supplied as a desktop unit.  
2.3.2  
2.3.3  
2.3.4  
Ventilation  
Ensure that the location planned for the installation of the unit is well ventilated. Take note of  
the locations of the cooling vents in the unit's enclosure and ensure that they are not  
obstructed.  
Temperature  
Observe the unit's ambient temperature specifications when choosing an installation space.  
Extremes of heat or cold beyond the specified operating temperature limits may cause the  
unit to fail. Do not install the unit on top of hot equipment.  
قوة إمداد تموين  
Ensure that the site's AC power supply is stable and within the rated voltage of the unit. If the  
site's AC power is likely to have spikes or power dips, use power line conditioning or an  
uninterrupted power supply (UPS).  
2.3.5  
Environment  
The unit is designed to operate in a clean office environment. Elevated levels of dust may  
cause the unit to fail.  
2.4  
Associated equipment  
A typical system could contain the following components (not included with the unit):  
Primary VGA monitor for multiscreen monitoring (monitor A)  
Second CVBS monitor for spot/alarm monitoring (monitor B)  
Cameras with 1 Vpp composite video outputs  
Amplified microphone  
Audio amplifier with speaker  
Video coaxial cable with BNC connectors for connecting the video signals  
Audio cable with RCA connectors for connecting audio signals.  
AC power supply outlet for the unit that allows for secure isolation (for operational  
reasons, the unit has no on/off switch)  
PC and network for remote applications  
Pan/tilt/zoom control units  
2.5  
Warranty  
Failure to follow the Safety Instructions, Installation Instructions, and any other instructions  
noted in this manual may result in damage to the unit and void the warranty.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
               
16 en | Quick install  
Digital Video Recorder 440/480 Series  
3
Quick install  
To get the unit quickly operational, make the connections described below and then enter the  
relevant data in the Quick install menu. The Quick install menu appears the first time the unit  
is started.  
3.1  
Connections  
Figure 3.1 Back panel connections for the 4-channel model*  
* 8-channel models have 8 video connectors and 2 alarm input connectors.  
3.1.1  
3.1.2  
Primary connections  
1. Connect the cameras to the VIDEO IN BNC connectors.  
2. Connect monitor A to the VGA MON A output (supporting 800x600, 1024x768, or  
1280x1024).  
3. Connect a USB mouse to the USB port.  
Optional connections  
1. Connect monitor B to the C MON B BNC connector.  
2. Connect an audio signal to the AUDIO IN RCA (CINCH) input.  
3. Connect the AUDIO OUT RCA (CINCH) output to the monitor or an audio amplifier.  
4. Connect up to 4/8 alarms to the ALARM IN inputs (via the supplied terminal blocks).  
5. Connect the ALARM OUT output (via the supplied terminal blocks).  
6. Connect a pan/tilt/zoom control unit to the RS-485 port (via the supplied terminal block).  
7. Connect to your network via the RJ-45 Ethernet port.  
8. Connect a “Bosch RS232 to Bi-phase converter” to the RS-232 port if required.  
3.1.3  
Powering up  
Switch on all connected equipment.  
Connect the power unit to the AC power outlet.  
Connect the DC power cord to the 12VDC connector on the unit.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
         
Digital Video Recorder 440/480 Series  
Quick install | en  
17  
3.2  
First-time use  
The Quick install menu opens the first time the unit is used. Fill in the basic settings in the  
three tabs to get the unit operational. The unit begins recording automatically when the Quick  
install menu is closed.  
To open the Quick install menu at any other time:  
1. Press the menu  
key to bring up the System Control Bar.  
2. Press the menu  
key again to enter the main menu.  
The main menu appears on monitor A.  
3. Select System, then the Configuration submenu, and finally Quick install.  
Navigating  
Use a USB mouse or the following front panel keys:  
Use the enter  
Use the arrow  
Use the exit  
key to select a submenu or item.  
keys to move through a menu or list.  
key to go back or to switch off the menu.  
After bootup, the unit shows the log-in screen over a quad display. The default User ID is  
ADMINISTRATOR, the default password is 000000(six zeros).  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
18 en | Quick install  
Digital Video Recorder 440/480 Series  
3.3  
Quick install menu  
The Quick install menu contains three tabs: International, Continuous Recording, and  
Network. Click the Exit button to exit the Quick install menu. Changing Quick install settings  
overwrites customized settings.  
3.3.1  
International  
Figure 3.2 Quick install - International  
لغة  
Time zone  
Time format  
Time  
Select the language for the menu from the list.  
Select a time zone from the list.  
Select either a 12 or a 24 hour clock format.  
Fill in the current time.  
Date format  
Select from three date formats which show either the month (MM),  
the day (DD), or the year (YYYY) first.  
Date  
Fill in the current date.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
   
Digital Video Recorder 440/480 Series  
Quick install | en  
19  
3.3.2  
Continuous Recording  
Figure 3.3 Quick install - Continuous Recording  
Set the Continuous Recording Resolution, Quality, Frame rate, Covert, and Audio for each  
profile in the table.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
20 en | Quick install  
Digital Video Recorder 440/480 Series  
3.3.3  
Network  
Figure 3.4 Quick install - Network  
Fill in the settings that control the behavior of the unit with respect to a network.  
DVR ID  
DHCP  
Enter a unique DVR ID to be used in the network.  
Enable DHCP to have IP address, subnet mask, and default  
gateway assigned automatically by the network server.  
The actual values are displayed.  
IP address, Subnet  
mask, and Gateway  
Fill in the IP, subnet mask, gateway addresses, and DNS server  
addresses when DHCP is not enabled.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Hardware setup | en  
21  
4
Hardware setup  
This chapter contains detailed information about the hardware installation and connection of  
external equipment to the unit. The connector types and their pin signals are described. Most  
of the connectors are located at the rear panel of the unit. For convenience, one USB port is  
located on the front of the unit to connect a mouse or memory device.  
All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits should  
only be connected to other SELV circuits.  
4.1  
Camera connections  
Connect cameras to the VIDEO IN connectors on the back of the unit using 75 ohm video  
coaxial cables with BNC connectors.  
The unit automatically configures itself as a PAL or NTSC unit. The unit determines the  
standard by detecting the signal format of the VIDEO IN 1 during startup. The unit can also be  
manually set to PAL or NTSC in the ‘Camera menu’ under ‘Video format’.  
Specifications  
Input signal: Composite video 1 Vpp, 75 ohm  
Color standard: PAL/NTSC, auto-detect  
Gain control: Automatic gain control for each video input  
Connector type: BNC  
Figure 4.1 Camera video inputs - 4 channels  
4.2  
Audio connections  
The unit has 1 audio input and 1 audio output. Connect using audio cable with RCA (CINCH)  
compatible connectors.  
Specifications  
Input signal: Mono RCA (CINCH), 1 Vpp, 10k ohm  
Output signal: Mono RCA (CINCH), 1 Vpp, 10k ohm  
Figure 4.2 Audio output and input connectors  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
     
22 en | Hardware setup  
Digital Video Recorder 440/480 Series  
4.3  
Monitor connections  
Up to two monitors can be connected through the VGA and CVBS connections.  
4.3.1  
VGA (Monitor A)  
Connect the unit to one VGA monitor using standard VGA cable. It is advised to use 17”  
monitors or larger when using LCD(s).  
Specifications  
Output signal: VGA  
Resolution: 800x600, 1024x768, or 1280x1024  
Color: True color (32 bit)  
Connector type: DE-15  
Figure 4.3 VGA monitor connector  
4.3.2  
CVBS  
Connect the unit to a CCTV monitor using 75 ohm video coaxial cables with BNC connectors.  
The unit provides a 1 Vpp CVBS signal.  
If the monitor has a loop-through connection and the loop-through output is available, select  
the 75 ohm impedance setting on the monitor. If the monitor's loop-through output is  
connected to an additional device, the device's termination is set to 75 ohm and the monitor's  
termination is set to high impedance.  
Note: This is not necessary on devices with automatic termination.  
Specifications  
Output signal: Composite video 1Vpp, 75 ohm, Sync. 0.3Vpp 10%  
Resolution: 720x576 PAL, 720x484 NTSC  
Connector type: BNC  
Figure 4.4 CVBS monitor connector  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
     
Digital Video Recorder 440/480 Series  
Hardware setup | en  
23  
4.4  
RS-232 COM port connections  
The RS-232 COM port is used to connect a PC to the unit for service purposes or to connect a  
Bosch “RS-232 to Bi-Phase Converter”. For service purposes, use a null-modem cable to  
connect the serial port of the PC to the unit. The Baud rate can be selected in the menu  
system.  
Specifications  
Connector type: 9-pole D-type male connector  
Maximum input voltage: 25V  
Communicaton protocol: Output signals according EIA/TIA-232-F  
Figure 4.5 RS-232 COM port connector  
Signal name  
Pin number  
Description  
DCD_in  
1
2
3
4
5
6
7
8
9
Carrier detection signal (not used)  
RS-232 receive signal  
RS-232 transmit signal  
No connection  
RX  
TX  
N/C  
System ground  
System ground  
N/C  
RTS  
CTS  
N/C  
No connection  
RS-232 request to send signal  
RS-232 clear to send signal  
No connection  
Table 4.1 RS232 console port socket  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
 
24 en | Hardware setup  
Digital Video Recorder 440/480 Series  
4.5  
Ethernet connection  
The standard RJ-45 Ethernet socket is used to connect the unit directly to a PC or to a  
network. To connect directly to a network hub, use a straight-through network cable. To  
connect directly to a PC, use a cross-over network cable. Consult with your local IT personnel  
for the specific type of cable needed. The maximum cable length from node to node is limited  
to 100 meters (300 feet).  
Specifications  
Connection: 10/100 BaseT, IEEE 802.3  
Differential signal voltage: 2.8 V maximum, inputs have transient overvoltage protection  
Ethernet port details: EEE 802.3/802.3u — 100Base-TX/10Base-T physical layer  
Auto negotiation: 10/100, full/half duplex  
Cable length: 100 meters (100 ohm unshielded twisted pair cable or 150 ohm shielded  
twisted pair cable, category 5 or higher).  
Impedance: built-in compensation for impedance matching  
Indicators: ACT, 10/100  
Figure 4.6 RJ-45 Ethernet connector  
Signal name  
LAN_TX +  
LAN_TX -  
LAN_RX +  
N/C  
Pin number  
Description  
1
2
3
4
5
6
7
8
Ethernet transmit line plus  
Ethernet transmit line minus  
Ethernet receive line plus  
No connection  
N/C  
No connection  
LAN_RX -  
N/C  
Ethernet receive line minus  
No connection  
N/C  
No connection  
Table 4.2 LAN - RJ-45 Ethernet socket  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Bosch Security Systems  
 
Digital Video Recorder 440/480 Series  
Hardware setup | en  
25  
4.6  
USB connectors  
A USB 2.0 connector is located at the rear panel of the unit to which a mouse, for example,  
can be connected. For convenience, the USB 2.0 port is located on the front of the unit to  
connect a mouse or USB memory device. (Recording to a USB-drive is not supported.)  
Figure 4.7 USB connector (on front and on rear)  
4.7  
RS485 port  
Connect Bosch or third-party controllable cameras to the unit for pan, tilt, and zoom control.  
The Bosch protocol is supported with the following baud settings:  
9600 baud  
8 data bits  
1 stop bit  
no parity  
no flow control  
Figure 4.8 RS-485 connector  
Signal name  
TX -  
Pin number  
Description  
1
2
3
Data transmission  
Data transmission  
Shield  
TX +  
GND  
Table 4.3 RS485 pin definition  
The recommended cable cross section is AWG 28-16 (0.08-1.5 mm2).  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
   
26 en | Hardware setup  
Digital Video Recorder 440/480 Series  
4.8  
External alarm I/O connection  
Alarm inputs and outputs are supplied screw down terminal blocks. The screw terminal blocks  
are supplied with the unit.  
Connecting the inputs  
Each (alarm) input line can be switched by a contact from external devices. Wire them as  
either Normally Open (N/O) or Normally Closed (N/C). Configure the alarm inputs as N/O or  
N/C in the menu system. The default is N/O.  
Specifications  
Alarm input impedence: Internal pull-up 10 K to +5 V  
Input voltage range: -2 VDC minimum to 15 VDC maximum  
Input voltage threshold: low voltage 0.5 V maximum, high voltage 2 V minimum  
Cable cross section: AWG 26-16 (0.13-1.5 mm2)  
Connecting the alarm output  
The alarm output relay responds to input alarms and triggers. Configure the alarm output as  
N/O or N/C in the menu system. The relay is active for the duration of the driving event. Only  
connect resistive loads to the alarm output relays. Do not exceed 30 Vac, 24 Vdc, 500 mA  
(continuous), or 10 VA on an alarm output relay's contacts.  
DANGER!  
Electrical voltage.  
Risk of electric shock and damage to the unit.  
The contacts must not be used at AC line voltages.  
Specifications  
Switching current (resistive): 500 mA maximum  
Switching voltage (resistive): 30 VAC/24 VDC maximum  
Cable cross section: AWG 26-16 (0.13-1.5 mm2)  
Figure 4.9 Alarm output connector for 4 channels  
Figure 4.10 Alarm output connector  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Hardware setup | en  
27  
4.9  
Power supply  
DC power is supplied to the unit from an AC/DC power supply unit delivered with the unit. For  
operational reasons, the unit has no on/off switch. This means that the unit is always powered  
as long as the power cable from the power supply unit is connected to the 12VDC socket.  
Specifications:  
External power supply unit:  
AC input: 100-240 VAC; 1.8 A; 50/60 Hz  
DC output: 12 VDC; 3 A  
DVR power input: 12 VDC; 3 A  
Figure 4.11 12 VDC power supply socket  
4.10  
Maintenance  
Maintenance of this unit is limited to external cleaning and inspection. Refer all servicing to  
qualified service personnel.  
DANGER!  
Electrical voltage. Risk of electric shock.  
Do not open the top cover or attempt to service the unit. No user serviceable parts inside.  
Refer all servicing to qualified service personnel. Opening the top cover will void the warranty!  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
   
28 en | Operating instructions  
Digital Video Recorder 440/480 Series  
5
Operating instructions  
These instructions explain the purpose of the front panel keys.  
The functions available can be limited by setting passwords. Access to the unit’s functions are  
determined by the user level of the user logged in.  
Function  
View live  
Administrator level  
Advanced User level  
Normal User level  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
Yes  
Sequence  
Quad  
Yes  
Yes  
OSD  
Yes  
Zoom  
Yes  
Pan/Tilt/Zoom (PTZ)  
Playback  
Yes  
No (configurable)  
No (configurable)  
No (configurable)  
No (configurable)  
No  
Search  
Export  
Acknowledge Alarm  
System Menus  
Covert  
No  
No  
Table 5.1 User Levels and Permissions  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Bosch Security Systems  
 
Digital Video Recorder 440/480 Series  
Operating instructions | en  
29  
5.1  
Front panel controls  
400 series  
Figure 5.1 Front panel controls - 4-channel model  
400 series  
Figure 5.2 Front panel controls - 8-channel model  
5.1.1  
Keys  
The keys on the front panel control all functions. Symbols on the keys show the functions.  
Inactive keys emit an audible beep when pressed.  
Arrow keys:  
Up,  
Down,  
Left,  
Right  
move around through menu items or values when in menu mode  
in PTZ mode, the arrow keys can be used to control the pan or tilt functions of the  
selected camera  
moves the visible area of the selected image in digital zoom mode  
Enter key  
selects a submenu or menu item, or confirms selections made in menus  
displays the cameo submenu in full screen or quad modes  
Menu key  
opens the system menu  
Search key  
press to open the date/time search menu to look for recorded images  
Export key  
press to open the export menu  
PTZ key  
enables or disables the PTZ mode  
Zoom in key  
PTZ zoom in key  
Digital zoom in key on active full-screen display  
Zoom out key  
PTZ zoom out key  
Digital zoom out key  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
   
30 en | Operating instructions  
Digital Video Recorder 440/480 Series  
Exit key  
press to return to previous level or to exit the menu system  
Alarm indicator / acknowledge key  
flashes when an alarm is detected  
press to acknowledge an alarm event; an indicator light is located on the key  
Camera keys (1-4)/(1-8)  
press to see a full-screen display of the video input  
the LED lights when the camera is recording  
the LED flashes during an alarm on the camera  
Quad key  
press to go to quad mode  
in quad mode, press to toggle to full screen  
Sequence key  
view cameras in sequence on full-screen or quad displays  
OSD key  
press to view date/time and camera information, date/time only, or none  
Digital zoom key (4-channel model)  
press to zoom in on the active full screen camera display  
Multi-screen key (8-channel model)  
press to go to different multi-screen modes  
Pause key  
press to freeze the picture  
Reverse key  
in live mode, press to start reverse playback of recordings for the displayed cameras  
in playback mode, press to start or speed up reverse playback  
in pause mode, press to step back one frame  
Play key  
in live mode, press to resume playback from the last selected playback position  
in pause or fast forward/reverse modes, press to resume playback  
Fast forward key  
in live mode, press to start playback from one minute earlier  
in playback mode, press to speed up the forward playback rate  
in reverse playback mode, press to start forward playback  
in pause mode, press to step forward one frame  
Stop key  
while in playback mode, press to return to live mode  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Digital Video Recorder 440/480 Series  
Operating instructions | en  
31  
5.1.2  
Indicators  
The indicators on the front panel display light or flash to alert of various operating conditions.  
Power - lights green when the unit is powered  
Network - lights green when a remote user is connected to the unit  
Record - lights red when the unit is recording video  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
32 en | Operating instructions  
Digital Video Recorder 440/480 Series  
5.2  
Mouse Controls  
All functions controlled by the front panel can, alternatively, be accessed using a USB mouse.  
All main DVR functions are accessible via the System Control Bar. To display the panel  
(monitor A only), move the mouse pointer to the bottom left of the screen or press the menu  
key. To close the System Control Bar press the exit  
key.  
Figure 5.3 System Control Bar  
The buttons and indicators of the System Control Bar work the same as the keys and  
indicators on the front panel.  
The System Control Bar can also be controlled with the Arrow Keys and Enter Key.  
5.3  
Remote control  
All functions controlled by the front panel and USB mouse can, alternatively, be accessed  
using the supplied remote control. The IR remote control allows control of up to nine units  
without interfering with one another.  
An ID number must be set on the remote control and in the system. See Section 6.6.7 System,  
Page 74 for setting the system ID for the unit.  
To set the ID on the remote control:  
1. Press the ID button on the remote control.  
2. Press a number between 1 and 9 that corresponds to the unit ID you wish to control.  
Figure 5.4 Remote control  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Operating instructions | en  
33  
5.4  
Viewing pictures  
The unit has two monitor outputs, A and B. The way in which these monitors display pictures  
depends on how the system is configured.  
5.4.1  
Monitor A  
Monitor A is the main monitor. It shows full-screen, quad or multiscreen live or playback  
camera pictures. Status messages, alarms, motion, and video loss warnings are also displayed  
on this monitor. When the menu system is activated, it is displayed on this monitor. Monitor A  
is the default monitor for keyboard and mouse commands.  
Changing the full-screen display on Monitor A  
To control the display on monitor A with mouse control:  
1. Display the System Control Bar.  
2. Click  
.
3. From the pop-up menu, select the display for Monitor A  
Select 1-4/8 for the corresponding Camera  
Select the sequence key to sequence channels 1-4/8  
Changing the quad/3x3 display on Monitor A  
To control the quad/3x3 display on monitor A with mouse control:  
1. Display the System Control Bar.  
2. Click  
.
3. From the pop-up menu, select the display for Monitor A  
Select the quad key  
to select the quad mode  
Select the multiscreen key  
to select the 3x3 mode (DVR 480 only)  
key to sequence the quad mode  
Select the sequence  
5.4.2  
Monitor B  
Monitor B displays full-screen, quad or multiscreen (with or without sequence) of live  
pictures. When an alarm or motion input is detected, the camera picture with the Alarm/  
Motion indicator can be displayed on monitor B. When multiple alarms or motion occur,  
camera pictures are sequenced on monitor B.  
Changing the full-screen display on Monitor B  
To control the display on monitor B with mouse control:  
1. Bring up the System Control Bar.  
2. Click the Monitor B  
button.  
3. From the pop-up menu, select the display for Monitor B  
Select 1-8/16 for the corresponding Camera  
Select the sequence key to sequence channels 1-8/16  
Changing the quad display on Monitor B  
To control the quad display on monitor B with mouse control:  
1. Bring up the System Control Bar.  
2. Click the Monitor B  
button.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
     
34 en | Operating instructions  
Digital Video Recorder 440/480 Series  
3. From the pop-up menu, select the display for Monitor B  
Select the quad key  
Select the sequence  
to select the quad mode  
key to sequence the quad mode  
5.4.3  
Viewing  
The tables show all possible views for monitor A. The set of muti-screen views available  
depends on the resolution (aspect ratio) setting and the model type (4 or 8 channels).  
Resolution (aspect ratio) 800x600 (4:3), 1024x768 (4:3), 1280x1024 (5:4)  
Full screen  
Quad  
3x3 (not for 4-channel model)  
Table 5.2 Multi-screen viewing in 4:3 and 5:4  
Quad screen  
To view quad displays:  
Press the quad  
key.  
A quad display of camera pictures appears on the active monitor.  
Full-screen  
To view a full-screen shot of a camera:  
Press a camera key.  
A full-screen shot of the camera that was selected appears.  
Multi-screen  
To view multi-screen displays on monitor A:  
Press the multi-screen  
key.  
A multi-screen display of camera pictures appears on the active monitor.  
Sequence  
To view a sequence of live camera pictures of several cameras:  
1. Press the sequence key.  
A sequence of camera pictures appears, each for a pre-programmed dwell time.  
2. Press the sequence  
key to stop sequencing.  
Cameo assignment  
The cameo assignment is used in playback mode as well as in live mode.  
Assigning cameras to cameos in a quad or multi-screen view:  
1. Use the arrow keys to select a cameo.  
The cameo with the yellow border is the selected cameo.  
2. Press the enter  
key to display the Cameo Menu.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Operating instructions | en  
35  
3. Use the arrow keys to select a camera number (4 or 8) to put in the cameo and press the  
enter key.  
Alternatively, right click a cameo with the mouse and choose a video input from the Cameo  
Menu.  
Freeze image  
Freezing a camera shot on monitor A:  
1. Press the pause  
key to freeze all the picture in the active cameo.  
2. Press the stop  
key to return to live viewing.  
3. Alternatively, right click in the active cameo and select Freeze or Unfreeze from the  
context menu using the mouse.  
Zoom  
To zoom in on a video image:  
1. Press the zoom in  
The picture is enlarged by a factor of 2.  
2. Use the arrow keys to select the area of the picture to be displayed.  
key.  
3. Press the zoom out  
key to return to a full picture and leave the zoom mode.  
Alternatively, right click and select Zoom or Exit zoom to enable or disable zoom mode with  
the mouse. While in zoom mode, move the mouse pointer to select the area of the picture to  
be displayed.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
36 en | Operating instructions  
Digital Video Recorder 440/480 Series  
5.5  
Live and playback  
5.5.1  
Live mode  
The live mode is the normal operating mode of the unit where live pictures are viewed from  
the cameras. From live mode, switch to playback mode or the system menu.  
5.5.2  
Playback mode  
Access to playback functions requires the right user level. Discuss this with your  
administrator. To enter playback mode:  
1. To switch the unit from live to playback mode:  
press the play  
key  
press the forward  
key for instant playback, which will cause the unit to enter  
playback at 90 seconds before the current time  
perform a search  
perform an action from the cameo menu.  
2. In playback mode the video control keys operate as follows:  
Press the rewind  
key to start reverse playback of recordings. Pressing it again and  
again increases the display rate to a maximum before returning it back to normal speed  
again. Press the rewind  
key in the pause mode to step back one frame at a time.  
Press the pause  
key to freeze the picture.  
Press the forward  
key to start playback of recordings. Pressing it again and again  
increases the display rate to a maximum before returning it back to normal speed again.  
Press the forward  
Press the play  
key in the pause mode to step forward one frame at a time.  
key to resume playback.  
Press the stop  
live viewing.  
key to switch back to live viewing. An alarm also switches the unit back to  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
     
Digital Video Recorder 440/480 Series  
Operating instructions | en  
37  
5.6  
Overview of the menu system  
The Main menu gives access to several functions to help use the unit. Access to the Main  
menu is only possible with a User Account at the Administrator User Level. Access the Main  
menu via:  
the front panel keys,  
a USB mouse.  
Slight differences in navigation and selection are only due to the differences between the keys  
on the unit and the mouse. The menu structure is the same in all cases.  
The top menu consists of six menus with drop-down submenus.  
Figure 5.5 Main menu  
5.6.1  
Access using the front panel keys  
To open the Main menu, press the menu  
key twice.  
On the first press the System Control Bar appears on monitor A.  
On the second press the Main menu appears on monitor A.  
To move through a menu or list, use the arrow  
panel.  
keys on the front  
To select a submenu or item, use the enter  
key.  
To go back, use the exit  
key.  
To exit the menu, press the exit  
key.  
5.6.2  
Access using the mouse  
To open the menu, move the pointer to the bottom of the screen.  
The System Control Bar appears on monitor A.  
To open the menu, click the menu icon.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
     
38 en | Operating instructions  
Digital Video Recorder 440/480 Series  
5.6.3  
Main menu  
Camera  
The Camera menu is used to configure recording settings for the unit. The menu contains  
eight submenus:  
Camera - per camera Enable, Name of the camera, Covert, and Audio  
Video Adjustment - per camera Brightness, Contrast, and Color  
PTZ - per camera Port, Address, Protocol, and Baud Rate  
Continuous Recording - per camera Resolution, Quality, and Frame Rate  
Input Recording - per camera Resolution, Quality, Frame Rate, Pre-event, and Post-  
event  
Motion Recording - per camera Resolution, Quality, Frame Rate, Pre-event, and Post-  
event  
Network Live Streaming - per camera Enable, Resolution, Quality, and Frame Rate  
Video Format - NTSC, PAL, or Auto Detect; VGA Output - select required VGA  
resolution  
Schedule  
The Schedule menu is used to set recording types according to the hour and day of the week  
and for exception days.  
Display  
The Configuration menu contains three submenus:  
لغة - set the language option for the unit  
Monitor A - show Camera Name and Status, Date and Time, Playback and HDD Status,  
and configure Sequence Dwell Times  
Monitor B - show Camera Name and Status, Date and Time, and configure Sequence  
Dwell Times  
Event  
The Event menu contains four submenus:  
Input - per input Input Type, Camera, Relay Output, and PTZ preset  
Motion - per camera Sensitivity, Relay Output, and Area setup  
Alarm Acknowledge - Toggle between Post-event time and Manual  
System - enable alarms for Disk fail, Disk full, System/Disk temperature, Administrator  
Password change, Video loss, and Power On.  
Network  
The Network information menu contains four submenus:  
TCP/IP - enable DHCP, set IP Address, Subnet, Gateway, DNS, HTTP Port, and Bandwidth  
limit  
DDNS - set dynamic DNS for dyndns.org, sitesolutions.com, and tzo.com  
Notification - send e-mail notification on Input, Motion detect, Disk fail, Disk full, System/  
Disk temperature, Administrator Password change, Video loss, Power On  
Mail - set SMTP server, SSL, User name, Password, To 1-3, From, and Subject.  
System  
The System information menu contains seven submenus:  
Date/Time - set Date, Time, Date format, Time format, Time zone, and Daylight Savings  
NTP - set NTP Time Server and Sync interval  
Beeper - set unit to beep on Button, Input, Motion, System, or Video loss  
User - set Usernames, Passwords, and User Levels for Users 1-10  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Operating instructions | en  
39  
Configuration - Import and Export configuration, reset to Factory defaults, Update  
firmware and Quick install  
Hard Disk - set Overwrite, Disk full warning, Event partition, Auto delete, and format the  
disk  
System - set the DVR name, and Auto user logout time  
5.7  
Search  
To Search, press the search  
To Search using the mouse:  
key.  
1. Move the cursor to the bottom of the screen to access the System Control Bar.  
2. Click the search  
icon.  
The default search is a Date/time search.  
Figure 5.6 Main menu - Search  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
 
40 en | Operating instructions  
Digital Video Recorder 440/480 Series  
5.7.1  
Date/time search  
Select the start date. Once the start date has been selected, the timeline will update to show  
the full 24 hour period.  
1. Use the Zoom In button to magnify the timeline.  
2. Enter the start time:  
Enter the hour and minute.  
With a mouse, click directly on the timeline to set the start time.  
3. Click Play to start playback:  
Playback in all displayed cameos will start.  
Figure 5.7 Search menu - Date/Time Search options  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Operating instructions | en  
41  
5.7.2  
Event search  
1. From a Date/Time search, press the exit  
2. Press the left/right arrow keys to select Event Search.  
3. Press the enter key to activate the search.  
With the mouse, click the Event Search tab to make it active.  
key to select the Search Tabs.  
Search criteria  
Under Start and End, fill in date and time values to determine the time span of the  
search.  
Under Channel, specify the camera input to search for. The selected input is shown.  
Set Event Type to search for alarm events, motion events, or both. Set to All so that the  
search is not restricted by an event type.  
Select Search to start the search.  
Search results  
The recording fitting the filter and closest to the selected date and time is shown first.  
If more events than can be shown on the page are found use Page to see more  
results.  
Use the up/down arrow keys to move through the list.  
Press the Play button for a full-screen playback of the selected recording.  
Figure 5.8 Search menu - Event Search options  
Event Search results  
The event search results are indicated by a start and stop time of a small period of video.  
Within this period of video the event search results can be found.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
42 en | Operating instructions  
Digital Video Recorder 440/480 Series  
5.7.3  
Smart search  
1. From a Date/Time search, press the exit  
2. Press the left/right arrow keys to select Smart Search.  
3. Press the enter key to activate the search.  
With the mouse, click the Smart Search tab to make it active.  
key to select the Search Tabs.  
Search criteria  
Under Channel, specify the camera input to search for. The selected input will be shown.  
Under Start and End, fill in date and time values to determine the time span of the  
search.  
Set Sensitivity to determine the threshold for detecting change in the video.  
Set Area to limit the smart search to only the area effected.  
Select Search to start the search.  
Search results  
The recording fitting the filter and closest to the selected date and time is shown first.  
If more events than can be shown on the page are found, use Page to see more  
results.  
Figure 5.9 Search menu - Smart search options  
Use the up/down arrow keys to move through the list.  
Press the Play button for a full-screen playback of the selected recording.  
Smart Search results  
The smart search results are indicated by a start and stop time of a small period of video.  
Within this period of video the smart search results can be found.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Operating instructions | en  
43  
5.8  
Export  
The export menu is accessed by pressing the Export  
key on the Front Panel or from the  
System Control Bar. It allows writing segments of recorded video and audio to a USB storage  
device.  
Figure 5.10 Export menu  
1. Choose to record to a USB from the Target Device selection box.  
2. Select the Channel to archive.  
3. Fill in a Start time and End time for the video segments to archive.  
4. Click Export to create the archive.  
To erase a USB drive after it has been inserted, click the Format button.  
If the total size of the video segments is greater than the memory device’s free space,  
then only the first segments that fit are archived.  
5. Click File to save ‘Export history log file’ to USB.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
44 en | Operating instructions  
Digital Video Recorder 440/480 Series  
5.9  
System information  
The System information screen is accessed from the System Control Bar by pressing the  
System Information  
icon. The System information menu contains:  
Model Name  
Serial Number  
Video Format  
MAC Address  
IP Address  
Software Version  
Figure 5.11 System Control Bar - System information  
Click Video info to see more information about the video connections.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Operating instructions | en  
45  
Figure 5.12 System Control Bar - Video signals information  
The video information menu shows the video system that has been set and the inputs on  
which video signals have been detected.  
Click Hard disk to see more information about the hard disks.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
46 en | Operating instructions  
Digital Video Recorder 440/480 Series  
Figure 5.13 System Control Bar - Disk info  
The Disk info menu provides information on the size and usage data of the hard drives.  
Note:  
Only Bosch hard disks with a signature can be used. If the hard disk is not certified, it cannot  
be used for recording.  
Click System to return to the system information window.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Digital Video Recorder 440/480 Series  
Operating instructions | en  
47  
5.10  
Log  
The Log displays historic system events and is accessed from the System Control Bar by  
pressing the Log  
icon.  
Logbook filter  
From the Log display, make a selection of which system events to show.  
The Log shows the date, time, and event type of various system events.  
Log contents are ordered from latest to earliest.  
Figure 5.14 Logbook - Logbook filter  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
 
48 en | Operating instructions  
Digital Video Recorder 440/480 Series  
5.11  
Triggers and alarms  
Various types of events change the way the unit works. These events are:  
an alarm input signal applied to the unit  
motion detection in a camera signal  
a loss of video from one of the cameras  
an internal alert from the unit itself (i.e. disk failure, temperature alarm)  
The way the unit reacts to events depends on how it is programmed.  
An event can cause either a trigger or an alarm. A trigger changes the way the unit works but  
does not require a response from the user. An alarm also changes the way the unit works but,  
in addition, usually activates several indicators and requires the user to acknowledge the  
alarm situation.  
The unit reacts to an event in any one of the following ways:  
Alarms  
A beeper sounds.  
A status message is displayed.  
An alarm icon is displayed.  
The border around a cameo changes color to red.  
An alarm  
or video loss  
indicator flashes.  
An output relay is activated.  
Triggers  
A motion  
indicator flashes.  
The view modes on the monitors change.  
A controllable camera might be moved to a pre-defined position.  
Recording behavior changes.  
The unit changes the way it operates via pre-defined profiles.  
Background events  
Triggers and alarms can change background tasks that a user may not notice. Unit responses  
that are not visible to the user are, for example, a change in recording speed, the activation of  
the output relay, and event logging. The unit can also be configured to record upon the  
activation of an alarm input. A trigger may change the way the camera images are displayed on  
the monitors without requiring intervention.  
5.11.1  
Alarm inputs  
If an input causes an alarm  
Monitors A and B can switch to a pre-programmed view mode.  
Monitor A: The border around the displayed cameos is red. The alarm icon is displayed in  
the corresponding cameo. An alarm status message is displayed.  
Monitor B: Full screen or sequenced display of pre-programmed cameras.  
The alarm beeper sounds. The alarm  
indicators flash.  
A controllable camera might be moved to a pre-defined position.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
   
Digital Video Recorder 440/480 Series  
Operating instructions | en  
49  
Acknowledging an input alarm  
Press the acknowledge  
key to acknowledge the alarm.  
The beeper is silent.  
The alarm  
indicators are no longer lit.  
The alarm status message disappears.  
The last-used view mode is restored.  
The alarm icon remains visible as long as the input causing the alarm is active.  
If an alarm is not acknowledged, the beeper switches off after the dwell time but the alarm  
still needs to be acknowledged.  
If auto-acknowledge is enabled, the beeper and the alarm  
dwell time.  
indicators switch off after the  
5.11.2  
5.11.3  
Motion events  
If a motion detection signal causes an event  
Monitors A and B can switch to display the motion events.  
The motion icon is displayed in the corresponding cameo. An alarm status message is  
displayed.  
The motion  
indicator on the front panel flashes.  
Video loss alarm  
If the loss of a video signal causes an alarm:  
Monitor A and B will show the video loss indicator.  
Monitor A can switch to a multiscreen view. The lost camera signal is displayed as a black  
cameo with the video loss message. The border around the camera with the video loss is  
red. An alarm status message is displayed.  
The alarm beeper sounds.  
The video loss  
indicator is displayed until the video signal is restored.  
Acknowledging a video loss alarm  
Press the acknowledge  
key to acknowlede a video loss alarm.  
The beeper is silent.  
The alarm status message disappears.  
The last-used view mode is restored.  
If the camera with video loss is visible, the black cameo and the video loss message continue  
to be displayed as long as there is no video present.  
5.11.4  
Multiple alarms  
Monitor A can switch to a multiscreen view if more than one alarm occurs. The latest alarm  
status message is always shown. Press the acknowledge  
key to deactivate all alarms.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
     
50 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6
Configuration menu  
Access all the parameters that are used to configure the unit via the menu system. The large  
number of available parameters gives the opportunity to program extensive functionality.  
Administrator rights are required to access the configuration menus.  
There are four ways to access the menu system:  
the front panel keys,  
a USB mouse,  
remotely via the Web-based Configuration application.  
In all cases, the parameters available are the same. Slight differences in navigation and  
selection are due only to the differences between the keys on the unit, the mouse, and the  
interface of the Web browser. The menu structure is the same in all cases.  
This chapter explains how to access the menus locally on the unit. It also documents the  
structure of the configuration menu system.  
The configuration menu is accessed from the top menu. The settings submenus give access to  
all configurable items for the unit.  
Figure 6.1 System Configuration menu  
The configuration menu has six major menu groups listed across the top. Each of these groups  
has a set of drop-down submenus which provide access to a screen where the values and  
functions can be selected and changed.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Configuration menu | en  
51  
Top tabs  
Camera  
Submenus  
Camera  
Video Adjustment  
PTZ  
Continuous Recording  
Input Recording  
Motion Recording  
Network Live Streaming  
Video Format  
Sunday  
Schedule  
Monday  
Tuesday  
Wednesday  
Thursday  
Friday  
Saturday  
Exception Days  
لغة  
Display  
Event  
Monitor A  
Monitor B  
Input  
Motion  
Alarm Acknowledge  
System  
TCP/IP  
Network  
System  
DDNS  
Notification  
Mail  
Date/Time  
NTP  
Beeper  
User  
Configuration  
Hard Disk  
System  
Table 6.1 System Configuration menu structure  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
52 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6.1  
Camera  
Use the Camera menu to configure the recording set up for each of the three profiles.  
1. Configure the settings for Continuous, Input, and Motion recording.  
Continuous recording - the default recording mode  
Input recording - activated upon an input contact event  
Motion recording - activated upon a motion event  
2. Choose an input channel to configure the settings for an individual video and audio input.  
6.1.1  
Camera  
Figure 6.2 Camera - Camera  
Use this menu to enable the video and audio inputs.  
Enable  
This setting enables or disables the video and corresponding audio inputs.  
Name  
Enter a name for the selected input. The name can be up to 16 characters long.  
Covert  
This setting enables or disables the hiding video from unauthorized users. When enabled  
Advanced, Normal and unauthenticated Users will be shown only a blank screen, equivalent to  
the camera being disabled. Administrator level users are able to view live, playback, and  
archive covert video.  
Audio  
Enable Audio input when an audio source is connected for the specified channel.  
Note:  
Disabling channels will allow increasing the frame rate or resolution on the remaining enabled  
channels.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
   
Digital Video Recorder 440/480 Series  
Configuration menu | en  
53  
6.1.2  
Maximum frame rates DVR 440  
Channels Enabled  
CIF  
2CIF  
4CIF  
4
3
2
1
25/30  
25/30  
25/30  
25/30  
25/30  
25/30  
25/30  
25/30  
12.5/15  
12.5/15  
25/30  
25/30  
Table 6.2 Maximum Frame Rates (PAL/NTSC IPS) by Resolutions for enabled Channels  
6.1.3  
Maximum frame rates DVR 480  
Channels Enabled  
CIF  
2CIF  
4CIF  
8
7
6
5
4
3
2
1
25/30  
25/30  
25/30  
25/30  
25/30  
25/30  
25/30  
25/30  
12.5/15  
12.5/15  
12.5/15  
12.5/15  
25/30  
6.25/7.5  
6.25/7.5  
6.25/7.5  
6.25/7.5  
12.5/15  
12.5/15  
25/30  
25/30  
25/30  
25/30  
25/30  
Table 6.3 Maximum Frame Rates (PAL/NTSC IPS) by Resolutions for enabled Channels  
6.1.4  
Video adjustment  
Figure 6.3 Camera - Video adjustment  
Channel  
Select the camera channel for adjustment. The preview displays the channel indicated.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
     
54 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6.1.5  
PTZ  
Figure 6.4 Camera - PTZ  
Select a COM Port, Control ID, and Protocol for PTZ when a controllable camera is  
connected.  
Pan and Tilt can be tested within the menu.  
By default, PTZ is disabled for all inputs.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Configuration menu | en  
55  
6.1.6  
Continuous Recording  
Figure 6.5 Camera - Continuous Recording  
Continuous recording mode:  
Resolution - set the video resolution to 4CIF (704x576/480 PAL/NTSC), 2CIF (704x288/  
240 PAL/NTSC), or CIF (352x288/240 PAL/NTSC).  
Quality - set the video quality setting to Best, High, Normal, Low, or Lowest.  
Frame rate - set the video frame rate to 25/30, 12.5/15, 6.25/7.5, 5/6, 2.5/3, or 1/1 IPS  
(Images Per Second in PAL/NTSC).  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
56 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6.1.7  
Input Recording  
Figure 6.6 Camera - Input Recording  
Use the same procedure as in Continuous Recording.  
Pre-event  
Pre-event recording can be switched off or to a displayed pre-event recording time by input  
and motion recording. The pre-event recording time is dependent on video complexity,  
resolution, quality, and frame rate settings.  
Post-event  
Post-event recording duration can be set between 10 seconds and 10 minutes, or set to  
Follow the alarm state.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Configuration menu | en  
57  
6.1.8  
Motion Recording  
Figure 6.7 Camera - Motion Recording  
Use the same procedure as in Input Recording.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
58 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6.1.9  
Network Live Streaming  
Figure 6.8 Camera - Network Live Streaming  
Use the same procedure as Continuous Recording to set the values for cameras that will be  
streamed over the network.  
Network Streams are not recorded.  
Network Streaming performance is limited by the total bandwidth between the unit and  
the PC running the Web-based control application.  
Note:  
Disabling channels will allow increasing the frame rate on the remaining enabled channels.  
Channels Enabled (4)  
CIF  
4
3
2
1
12.5/15  
12.5/15  
25/30  
25/30  
Table 6.4 Maximum Frame Rates (PAL/NTSC IPS) by Resolutions for enabled Channels (4)  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Configuration menu | en  
59  
Channels Enabled (8)  
CIF  
8
7
6
5
4
3
2
1
6.25/7.5  
6.25/7.5  
6.25/7.5  
6.25/7.5  
12.5/15  
12.5/15  
25/30  
25/30  
Table 6.5 Maximum Frame Rates (PAL/NTSC IPS) by Resolutions for enabled Channels (8)  
6.1.10  
Video format  
Figure 6.9 Camera - Video format  
Select the Video format, NTSC, PAL, or Auto detect, that the unit will operate with. When set  
to Auto detect, the format during startup of the video on the first channel where video is  
connected will be used to set the DVR to either PAL or NTSC.  
Select the VGA Output to match the best VGA resolution on the used VGA monitor  
(monitor A).  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
60 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6.2  
Schedule  
Setting the dynamic characteristics  
The settings in the Schedule menu provide the opportunity to tap the powerful functionality of  
the unit. By spending some time in planning and setting up the schedules, efficient use of  
resources is achieved while effectively covering most types of working situations.  
Recording is scheduled in a weekly calendar, changing the behavior at a particular date or  
time (for example, weekends or nights).  
Eight different record modes can be stored. Each record mode changes the quality and frame  
rate settings according to the settings in Continuous, Input, and Motion Recording.  
Figure 6.10 Schedule - Schedule  
The eight record modes are represented by four colors and four striped bands in a graphical  
representation of the weekly schedule. The schedule can be changed by selecting a time to  
select a recording mode.  
6.2.1  
Schedule  
Configuration:  
The use of a schedule is defined in a calendar that covers one week. This calendar is then  
repeated for subsequent weeks.  
A mode is specified at intervals of 1 hour for each day of the week.  
Program exception days to change profiles for special days and holidays.  
Edit:  
1. Select the first time to change mode and press the enter  
key to cycle the modes.  
Changing the mode sets the mode for all later time to the same mode.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
   
Digital Video Recorder 440/480 Series  
Configuration menu | en  
61  
2. Move to the next chronological mode change and press the enter  
next mode.  
key to cycle to the  
Use Day copy to copy the settings of the schedule to another day.  
Use Ch copy to copy the settings of the schedule to another channel.  
3. When finished, select Exit to save the updated schedule.  
Exception days  
Up to 32 exceptions can be set that override the schedule.  
To add an exception, select Add. Choose the date from the Calendar.  
To edit an exception, select List and then select the value to edit.  
To remove an exception, select List and click the Delete button.  
6.3  
Display  
6.3.1  
لغة  
Select a لغة from the list.  
6.3.2  
Monitor A  
Figure 6.11 Display - Monitor A  
1. Select which items are displayed on Monitor A when the OSD is active.  
2. Set the Sequence dwell time for each channel.  
The Sequence dwell time is used during Sequence or if multiple active events trigger the  
monitor.  
6.3.3  
Monitor B  
Use the same procedure as Monitor A.  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
       
62 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6.4  
Event  
Use the Event menu to specify the desired behavior for an Input, detected Motion, or System  
failures; also define how alarms are acknowledged.  
6.4.1  
Input  
Figure 6.12 Event - Input  
Inputs are always active on the unit.  
Input Type  
The Event behavior can be configured independantly for each channel.  
N.O. - Normally Open causes an alarm to tigger only when the circuit closes  
N.C. - Normally Closed causes an alarm to tigger only when the circuit is opened  
Camera  
Set the camera between 1 and 4, which is set to an alarm based on the input.  
Relay output  
Select the relay to trigger in response to the input.  
PTZ  
For the camera associated with the input, a PTZ preset can be sent to the camera to  
move to a specified pre-position.  
Enter a pre-position number from 1-255for each of the PTZ cameras that should be  
moved.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
   
Digital Video Recorder 440/480 Series  
Configuration menu | en  
63  
6.4.2  
Motion  
The motion detection feature can be configured by selecting the camera channel for each  
individual video input.  
Figure 6.13 Event - Motion  
1. Adjust the Sensitivity to set the theshold at which Motion is detected.  
2. Select the Relay Output to trigger in the event of Motion.  
3. To define the motion sensitive area in the Area preview cameo window:  
Draw in the preview cameo and press Enter to select a motion area.  
Use the arrow keys to move around the grid, pressing the enter key to toggle each  
grid block from active to inactive.  
Click Set All to set the selected area to its default value.  
4. Click Clear All to delete the selected area.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
64 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6.4.3  
Alarm acknowledge  
The alarm acknowledge feature can be configured for automatic or manual operation.  
Figure 6.14 Event - Alarm acknowledge  
Select the Post-event time to enable the unit to automatically acknowledge alarms when the  
post-event time is expired.  
Select Manual to require the operator to press the Acknowledge key to acknowledge an  
alarm.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Digital Video Recorder 440/480 Series  
Configuration menu | en  
65  
6.4.4  
System menu  
The relay outputs can be configured to react to system events.  
Figure 6.15 Event - System menu  
For each system event, select relay number 1 to activate an output relay when an events  
occurs, or select None for no activation.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
66 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6.5  
Network  
6.5.1  
TCP/IP  
Figure 6.16 Network - TCP/IP  
1. Enable DHCP to have the IP address, subnet mask, and default gateway assigned  
automatically by the network server.  
If DHCP is disabled, fill in the IP address, the Subnet mask, the default Gateway,  
and the Primary DNS server address. If required, change the default HTTP port no.  
(80) to a new value.  
2. Restrict the network Bandwidth limit by entering a value between 256 Kbps and  
100 Mbps. If 256 or 512_Kbps is selected, the DVR automatically selects I-frame only  
video at 1 IPS for transmission over the low bandwidth network connection.  
(A video clip is not attached to an e-mail if 256 or 512_Kbps is selected.)  
3. Enable the RTSP server to stream live video (for example, to a smart phone). If RTSP is  
enabled (on), enter a TCP/IP port number (default port 554).  
4. ICMP is set to Off by default (ping is not available). Set ICMP to On if you are using  
Control Center software version 3.34 or lower).  
6.5.2  
Streaming to mobile devices  
The Real Time Streaming Protocol (RTSP) feature allows live video streaming over the  
network.  
Attention:  
If you enable this feature (RTSP server to On) and the firewall on a ADSL router is opened,  
anybody can view the cameras. There is no log-on user ID or password to protect a camera  
live image.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
     
Digital Video Recorder 440/480 Series  
Configuration menu | en  
67  
6.5.3  
Connecting using a smart mobile phone  
Your smart phone should support RTSP network protocol and includes a RTSP capable player  
application that can display H.264 video streams. The RTSP transports the remote (network)  
stream or the local recording stream if the remote stream is disabled.  
Performance depends on the decoding performance of mobile device. Streaming may fail if  
the bandwidth of the internet connection is too low.  
You can connect to the DVR 600 to view one live-view channel as follows:  
1. Enable RTSP On in Network-TCP/IP menu for DVR 600.  
2. Set the DVR IP address in DHCP or enable static IP for DVR 600.  
3. Input the following on the smart phone.  
rtsp:// xxx.xxx.xxx.xxx/cgi-bin/rtspStream/1  
4. If the RTSP port is not the default port (554), use the following on the smart phone.  
rtsp://xxx.xxx.xxx.xxx:firewall open port/cgi-bin/rtspStream/1  
Note:  
xxx.xxx.xxx.xxx is the DVR IP address; 1 refers to channel 1, 2 refers to channel 2, etc.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
68 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6.5.4  
DDNS  
Figure 6.17 Network - DDNS  
Select a DDNS provider from the list and complete the details with the configuration  
information assigned by the provider. The providers supported are: dyndns.org, tzo.com, and  
sitessolutions.com.  
6.5.5  
Notification  
Figure 6.18 Network - Notification  
Select the events that will trigger the unit to send an e-mail.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
   
Digital Video Recorder 440/480 Series  
Configuration menu | en  
69  
6.5.6  
Mail  
Figure 6.19 Network - Mail  
1. Enable Send Mail to have an e-mail sent out from the system according to the settings in  
the Notification Menu.  
2. Use More E-mail Settings to set the From, Subject, and up to three recipients.  
The E-mail Test button will immediately generate an e-mail to help verify that the  
unit settings are correct.  
SMTP Server  
Set to the mail server that processes outgoing e-mail for your network. This can be either an  
IP address or a Fully Qualified Domain Name (ex. 10.0.0.1or smtp.example.com)  
SMTP Port Number  
This is the port the mail server receives e-mail on. The internet standard for e-mail is port 25,  
but some servers use different ports to protect against being used to transmit bulk,  
unsolicited e-mail.  
SSL  
Some mail servers require encryption to transmit e-mail. If required, this option allows SLL  
encryption to be used to send e-mail. If not required, do not enable this feature.  
User name and Password  
If authentication is required, regardless of encryption, enter the User name and Password  
provided by your administrator in each field respectively.  
More E-mail Settings - From  
This is the e-mail address that will appear as the sender of all e-mail originating from the unit.  
More E-mail Settings - Subject  
This is the subject that will appear in all e-mail sent by the unit.  
More E-mail Settings - To  
Enter up to three e-mail addresses that outgoing e-mail should be sent to.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
70 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6.6  
System  
6.6.1  
Date/Time  
Figure 6.20 System -Date/Time  
1. Enter the actual Date.  
2. Fill in the actual Time.  
3. Select a Date format which shows either the month (MM), the day (DD), or the year  
(YYYY) first.  
4. Select either a 12-hour or a 24-hour clock Time format.  
5. Select a Time zone from the list (daylight saving time must be set manually).  
6. Set Daylight Saving to On to enable it. Fill in the day, month, and time of both Start and  
End time, and the Offset if it differs from the information associated with your time zone.  
6.6.2  
NTP  
The Time server function synchronizes the time of the unit with the time of a network time  
server or another NTP-capable device. Choose either a Public Server to use a calibrated NTP  
server on the Internet, or select a Private Server to set your own time source. Fill in the IP  
address of the private network time server. Ensure that firewalls do not block NTP traffic via  
UDP port 123.  
1. Press NTP Test to start time synchronization.  
2. Set the Synchronization Interval to keep the unit closly matched with the time source.  
Intervals can be as frequent as hourly, or as long as monthly.  
6.6.3  
Beeper  
Select when the unit will Beep:  
On every Button press  
When the unit is triggered by an Input, Motion, System failure, or Video loss.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
       
Digital Video Recorder 440/480 Series  
Configuration menu | en  
71  
6.6.4  
Users  
Figure 6.21 System -User  
General  
The system contains a permanent Admin account with Administrator permissions. This user is  
logged in by default, e.g. after powering up the unit.  
Admin  
Enter a Password that can be up to 12 characters. The default Administrator password is  
000000(six zeros).  
User 1, 2... 9  
Up to nine users can be defined.  
1. Enter a User name up to 16 characters.  
2. Enter a Password up to 12 characters.  
3. Control access to the system by selecting a user Level.  
User Level can be set to Administrator, Advanced or Normal user.  
Figure 6.22 System - Change user rights for normal user  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
72 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6.6.5  
Configuration  
Figure 6.23 System - Configuration  
Import configuration will load previously saved system settings from a USB memory  
device.  
Export configuration saves a copy of the system settings to a USB memory device.  
Select Factory defaults to reset the settings in the menu system to their default values.  
Update firmware checks a USB memory device when connected for a new version of the  
unit software. Once started, the unit must not be powered off until the update is  
completed. See Section 2.1.3 Firmware upgrades.  
Quick install opens the Quick install menu that was first presented when the unit was  
powered on when received from the factory.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Configuration menu | en  
73  
6.6.6  
Hard Disk  
Figure 6.24 System - Hard disk  
The Hard Disk menu gives access to settings that affect video retention as well as a means to  
format the hard disk.  
Overwrite allows the unit to continuously record, overwriting the oldest unprotected  
video on the hard disk with newer video.  
The Disk full warning sets the threshold as which point the unit triggers an alarm  
indicating the drive is nearly full. This setting has no effect when Overwrite is in use.  
By default, the disk has only one partition where Continous and Event recordings are  
stored. This is the case when Event Partition is set to 0%.  
The disk can be segmented into two partitions by setting the Event Partition to a value  
greater than 0%. The first partition then stores video from Continuous Recording; the  
second partition the events recording. The Event Partition specifies the percentage of  
the hard disk dedicated to preserving video from Inputs and Motion.  
Auto delete sets a time window outside of which all video will be deleted from the unit.  
This function is primarily reserved to meet legal requirement in some jurisdictions.  
Format erases all data from the selected partition.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
74 en | Configuration menu  
Digital Video Recorder 440/480 Series  
6.6.7  
System  
Figure 6.25 System - System  
The System menu contains miscellaneous settings for the unit.  
IR remote control allows for up to nine units to recieve commands from a single remote  
control without interfering with one another. Once the number has been selected, set the  
corresponding ID on the remote control to continue to operate the unit.  
The DVR ID allows setting a unique ID for the unit. This name will be embedded in meta  
data included in exported video.  
Auto user logout sets the period of inactivity after which the user will be automatically  
logged out from the unit.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Web Client Software | en  
75  
7
Web Client Software  
The Web Client Software gives full remote control of the DVR 400 Series using a PC. Up to  
four remote users can access and control the unit. Remote live viewing, search, playback, and  
system configuration are provided. Remote control functions include pan, tilt, and zoom  
control of cameras, and video archiving. An on-line status overview of the connected unit is  
also provided.  
To access a unit, a user must log on using the same User ID and Password used for local  
access. The Web Client will follow the permissions of the user account, restricting the  
functions available to each remote user; for example, the ability to archive video. See  
Section 5 Operating instructions, page 28 chapter for more details on User Levels.  
7.1  
Getting started  
To use the Web Client, the unit and the PC must be able to connect via a TCP/IP network  
connection. Follow the instructions in Section 6.5 Network, page 66 to ensure the unit can be  
reached on the Network.  
7.1.1  
System requirements  
Operating platform: A PC running Windows XP, Windows Vista, or Windows 7.  
For the Configuration Tool, the recommended PC requirements are:  
Processor: Intel Core Duo, 2.0 GHz or comparable  
RAM memory: 2048 MB  
Free hard disk space: 10 MB  
Graphics card: NVIDIA GeForce 8600 or higher  
Network interface: 10/100-BaseT  
Web Browser: Internet Explorer 7 or later  
7.1.2  
Connecting to the DVR 400 Series the first time  
The video decoder and playback controller is automatically installed on the PC the first time  
the user connects the PC to the DVR:  
1. Open Internet Explorer.  
2. In the address bar, type the address of the unit.  
This can be either the IP address or a DDNS address, if enabled on the unit.  
3. Internet Explorer will prompt to install the OCX software that is used to show live and  
playback video.  
4. Once installed, the screen will refresh and prompt for a User ID and Password.  
Once installed on a PC, the Web Client will not need to install the OCX again unless  
a new version is released with a new unit firmware.  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
       
76 en | Web Client Software  
Digital Video Recorder 440/480 Series  
7.2  
How to log on  
When establishing a new connection to the unit, the Log on window appears.  
Figure 7.1 Web Client - Log on window via a network  
1. Type the User ID and Password.  
The User ID and Password are the same as those used to access the unit locally. The  
default User ID is ADMINISTRATOR, the default password is 000000(six zeros).  
2. Click Log on.  
Maximum number of users  
If the maximum number of users for the Web Client is exceeded, a window is displayed.  
7.2.1  
Menu structure differences  
The Web Client allows access to and use of unit menu items. These menu items are explained  
in Section 6 Configuration menu, page 50. Although the structure is the same, menus and  
settings behave differently because of the Web Browser.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
   
Digital Video Recorder 440/480 Series  
Web Client Software | en  
77  
7.3  
Introducing the browser window  
The browser window has three main areas:  
A mode bar across the top, with buttons for changing between live and playback, export,  
system settings, and buttons to toggle video between full screen, quad, or sequence.  
A vertical side bar that changes based on the context of the Mode Bar.  
The work space, showing video in the Live or Playback context, the export menu in the  
Export context, and system menus in the Configuration context.  
Figure 7.2 Web Client - Live  
7.4  
Live mode  
The live video window is shown by clicking the Live  
can:  
button. On this screen, the user  
view live video  
select different multiscreen displays  
assign cameras to cameos  
control ptz cameras  
monitor unit status and alarm conditions  
7.4.1  
PTZ camera control  
Pan and tilt  
To control the pan and tilt of PTZ cameras:  
1. Select the cameo of the camera to be controlled.  
2. Click and hold the up and down arrows for tilt.  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
     
78 en | Web Client Software  
Digital Video Recorder 440/480 Series  
3. Click and hold the left and right arrows to pan.  
4. Release the mouse button to stop camera movement controls.  
Zoom, focus, and iris  
To control the zoom, focus, and iris of PTZ cameras:  
1. Select the cameo of the camera to be controlled.  
2. Click and hold the left zoom button  
button to zoom in.  
3. Click and hold the left focus button  
button for near focus.  
4. Click and hold the left iris button  
button to open the iris.  
to zoom out; click and hold the right zoom  
for far focus; click and hold the right focus  
to close the iris; click and hold the right iris  
5. Release the mouse button to stop camera adjustment controls.  
Pre-position  
To move the active camera to a pre-position:  
1. Enter a pre-position number using the keyboard.  
2. Click Shot (or press enter).  
Click buttons one to six for immediate positioning to one of the first six pre-positions.  
To store the current position of the camera in a pre-position:  
1. Position the camera.  
2. Enter a pre-position number.  
3. Click Set.  
Aux commands  
Aux commands are special commands for controlling cameras. To switch on the Aux  
command:  
1. Enter an Aux number.  
2. Click Aux + (or press enter).  
3. To switch off the Aux command, click Aux -.  
7.4.2  
Camera views  
To switch the display mode, click one of the camera view  
change the cameo display configuration:  
buttons to  
Single  
view, Quad  
view, and Sequence  
display modes are available.  
Full Screen  
expands the current display mode to fill the entire screen. Press ESC to  
exit Full Screen.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Bosch Security Systems  
 
Digital Video Recorder 440/480 Series  
Web Client Software | en  
79  
7.5  
Playback mode  
Click the Playback  
button to show the playback window. On this screen, the user can:  
jump to a specific date and time to view playback video;  
view a graphical timeline of the day for recording, input, or motion events.  
Figure 7.3 Web Client - Playback  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
 
80 en | Web Client Software  
Digital Video Recorder 440/480 Series  
7.6  
Export mode  
Click the Export  
button to show the export window. On this screen, the user can:  
export a file remotely to the PC;  
choose the channel, audio, start and end date/times to export.  
Figure 7.4 Web Client - Export  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Web Client Software | en  
81  
7.7  
Configuration mode  
Click the Configuration  
button to enter the Configuration menu. This allows set up of all  
the configuration settings for the unit.  
Figure 7.5 Web Client - Configuration  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
 
82 en | Archive Player  
Digital Video Recorder 440/480 Series  
8
Archive Player  
8.1  
Getting started  
The Divar Archive Player allows viewing archived video recordings on a PC that have been  
archived from the DVR or Web Client. It also provides the opportunity to check the  
authenticity of the archived video.  
8.1.1  
System requirements  
Operating platform: A PC running Windows XP, Windows Vista, or Windows 7.  
For the Configuration Tool, the recommended PC requirements are:  
Processor: Intel Core Duo, 2.0 GHz or comparable  
RAM memory: 2048 MB  
Graphics card: NVIDIA GeForce 8600 or higher  
8.1.2  
8.1.3  
Installation  
The Archive Player does not require installation to function. When a video is archived, the  
Archive Player is automatically copied to the same directory as the archive file. Separate  
installation of the Archive Player is not necessary. When copying the archive file to other  
media afterwards, make sure to also copy the ArchivePlayer400 600.exefile as well.  
Starting the Program  
Double-click the ArchivePlayer400 600.exefile to start the program.  
To open a video archive  
When starting the program, a list of available archive files are displayed. Archive files are  
identified by the .400extension for the DVR 400 Series.  
Figure 8.1 Archive Player - Openning a video archive on startup  
1. Select an archive file to view.  
If the file is not listed, scroll down the list or choose the right location.  
2. Click Open.  
To exit the program, click Cancel or the close button.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
         
Digital Video Recorder 440/480 Series  
Archive Player | en  
83  
8.2  
Introducing the main window  
The main window appears upon selection of an archive file. The window is built up of three  
main areas:  
A horizontal top bar containing buttons for screen control.  
A vertical side bar containing buttons for camera selection and playback control.  
A video area displaying the video content and a playback slider bar.  
Figure 8.2 Archive Player - main window  
8.2.1  
Open button  
To open an archive, click the Open  
different archive file and click Open.  
button. The Open Video window appears. Select a  
8.3  
Camera Views  
To switch the display mode:  
1. Click one of the camera view buttons to change the cameo display configuration.  
Single  
Quad  
2. To change the zoom factor, drag the zoom slider.  
When zoom is selected, left click on the cameo to zoom in, right click to zoom out.  
Click, hold, and drag inside the cameo to move the image around.  
If your mouse has a scroll wheel, scroll up to zoom in, scroll down to zoom out.  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
     
84 en | Archive Player  
Digital Video Recorder 440/480 Series  
8.4  
Viewing Images  
8.4.1  
Assigning Cameos  
A cameo is a single camera picture in a multiscreen display.  
To assign a camera to a cameo:  
1. Click on a Cameo;  
the selected cameo has a yellow border.  
2. Double-click a camera from the list.  
To undo a cameo assignment:  
Click the close button on the cameo.  
If audio is present on the channel when a cameo is selected, it will be played.  
8.5  
Using the playback controls  
Figure 8.3 Archive Player - playback controls  
Play  
Click the Play  
button to play recorded video forward in the playback window:  
The playback speed depends on the setting of the speed  
slider.  
Some frames may be dropped depending on the PC resources, selected playback  
speed, or insufficient network bandwidth.  
Play Reverse  
Click the Play reverse  
button to play recorded video in reverse in the playback window:  
The playback speed depends on the setting of the speed  
slider.  
Some frames will be dropped in Play Reverse as a result of the compression  
process. Additional frames may be dropped as a result of the selected playback  
speed or insufficient network bandwidth.  
Playback Speed  
The slider controls the speed of the continuous forward and reverse play.  
Still  
Click the Still  
button to pause playback;  
The last image is shown as a still in the playback window.  
Step forward  
The step function is only enabled in the still mode.  
1. Click the Step forward  
button to move the image forward one frame.  
2. Hold it down to continue stepping at a maximum rate of 3 images per second.  
Step backward  
The step function is only enabled in the still mode.  
1. Click Step backward  
to move the image back one frame.  
2. Hold it down to continue stepping at a maximum rate of 3 images per second.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
     
Digital Video Recorder 440/480 Series  
Archive Player | en  
85  
8.5.1  
Capturing a still image  
Capture still images from the full screen display of a camera and save them to the PC hard  
disk in a bitmap format.  
To save an image from the active cameo to the PC hard disk:  
1. Click the Capture  
button;  
The Snapshot pop-up window appears.  
2. To change the default location, browse to the location in the PC file system where the  
image file is to be stored.  
3. Type a new name for the file to change the file name.  
4. Click Save.  
Authentication information is shown under the image.  
8.6  
Find image  
Figure 8.4 Archive Player - date and time fields and Go button  
1. Fill in a date and time.  
2. Click the Go  
button;  
Playback starts at the specified date and time.  
8.7  
8.8  
Video slider bar  
The video slider bar shows the relative playback time within the video interval and allows its  
adjustment.  
Checking authenticity  
1. Click the Check  
button to verify the authenticity of the archive:  
A progress bar will be displayed if the check takes some time.  
An information window indicates the authenticity of the archive.  
Verifying individual frames  
For authenticity verification of individual frames, pause playback and then click the  
information  
button. This opens the Authenticity information window. This window shows  
details of the video frame shown in the cameo when it was clicked.  
8.9  
Exit button  
Click the Exit  
button to stop using the Archive Player.  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
         
86 en | Menu default values  
Digital Video Recorder 440/480 Series  
9
Menu default values  
The following tables list the items of the menu system of the unit. The Default value column  
shows the values that are restored when the factory defaults item of the System settings  
menu is selected. An N in the Reset column means that this value is not reset when the  
factory defaults are recalled.  
Table 9.1 Quick Install menu default values  
Navigation  
Setting  
Default value  
AR  
GMT+0  
Reset  
International  
لغة  
Time zone  
Time format  
Time  
Y
N
N
N
N
Y
12-hour  
0:00  
Date format  
Resolution  
Video quality  
Frame rate  
Convert  
YYYY-MM-DD  
CIF  
Continuous Cameras 1-4  
Recording  
Normal  
30 (NTSC)/25 (PAL)  
Off  
Y
Y
Y
Network  
Setup  
DVR ID  
01  
Y
DHCP  
Enabled  
0.0.0.0  
N
N
N
N
IP address  
Subnet mask  
Gateway  
0.0.0.0  
0.0.0.0  
Table 9.2 Configuration menu default values  
Navigation  
Setting  
Default value  
Reset  
Camera  
Camera  
Cameras 1 ~ 4/8  
Enable  
Name  
Covert  
Audio  
On  
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Camera 1~4/8  
Off  
None  
50  
50  
50  
None  
00  
Bosch  
9600  
CIF  
Normal  
30(NTSC)/25(PAL)  
CIF  
Normal  
30(NTSC)/25(PAL)  
CIF  
Normal  
30(NTSC)/25(PAL)  
On  
CIF  
Normal  
15(NTSC)/12.5(PAL)  
Video Adjustment Cameras 1 ~ 4/8  
Brightness  
Contrast  
Color  
COM Port  
Control ID  
Protocol  
Baud Rate  
Resolution  
Quality  
Frame rate  
Resolution  
Quality  
Frame rate  
Resolution  
Quality  
PTZ  
Cameras 1 ~ 4/8  
Continuous  
Recording  
Cameras 1 ~ 4/8  
Cameras 1 ~ 4/8  
Input Recording  
Motion Recording Cameras 1 ~ 4/8  
Frame rate  
Enabled  
Resolution  
Quality  
Network Live  
Streaming  
Channels 1 ~ 4/8  
Frame rate  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
Digital Video Recorder 440/480 Series  
Menu default values | en  
87  
Table 9.2 Configuration menu default values  
Navigation  
Setting  
Default value  
Reset  
Schedule  
Sunday  
Monday  
Tuesday  
Wednesday  
Thursday  
Friday  
Saturday  
Exception Days  
لغة  
Monitor A  
Continous  
Continous  
Continous  
Continous  
Continous  
Continous  
Continous  
None  
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Display  
لغة  
AR  
On  
On  
Camera Name  
Camera Status  
Date/Time  
On  
Playback Date/Time On  
Playback Status  
HDD Status  
Event Popup  
On  
Off  
Off  
Camera 1 Dwell Time 2 sec  
Camera 2 Dwell Time 2 sec  
Camera 3 Dwell Time 2 sec  
Camera 4 Dwell Time 2 sec  
Monitor B  
Camera Name  
Camera Status  
Date/Time  
On  
On  
On  
Off  
Event Popup  
Camera 1 Dwell Time 2 sec  
Camera 2 Dwell Time 2 sec  
Camera 3 Dwell Time 2 sec  
Camera 4 Dwell Time 2 sec  
Event  
Input  
Input 1 ~ 4  
Input Type  
Camera  
Relay Output  
PTZ Preset  
Camera  
Sensitivity  
Relay Output  
Area  
N.O.  
1 ~ 4  
None  
None  
01:Name  
5
None  
All On  
Post-Event Time  
None  
Motion  
Camera 1 ~ 4  
Alarm acknowledge  
System  
Disk Fail  
Disk Full  
System/Disk Temp  
Admin Password  
None  
None  
None  
Changed  
Video Loss  
Power On  
None  
None  
Y
Y
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
88 en | Menu default values  
Digital Video Recorder 440/480 Series  
Table 9.2 Configuration menu default values  
Navigation  
Network  
Setting  
DHCP  
Default value  
Enabled  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
80  
Reset  
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Y
TCP/IP  
IP Address  
Subnet Mask  
Gateway  
Primary DNS  
Secondary DNS  
HTTP Port No.  
Bandwidth Limit  
RTSP Server  
RTSP PORT  
ICMP  
DDNS Server  
Host Name  
User Name  
Password  
Host Name  
Email  
100Mbps  
Off  
554  
Off  
DDNS  
Disabled  
EMPTY  
EMPTY  
EMPTY  
EMPTY  
EMPTY  
EMPTY  
EMPTY  
EMPTY  
EMPTY  
EMPTY  
Off  
dyndns.org  
tzo.com  
Key  
sitesolutions.com  
User Name  
Password  
Record ID  
FQDN  
Notification  
Input  
Motion Detect  
Disk Fail  
Off  
Off  
Y
Y
Disk Full  
Off  
Y
System/Disk Temp  
Admin Password  
Off  
Off  
Y
Y
Change  
Video Loss  
Power On  
Send Mail  
SMTP Server  
SMTP Port  
SSL  
User Name  
Password  
From  
Subject  
To (1)  
To (2)  
To (3)  
Off  
Off  
Off  
EMPTY  
25  
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Mail  
Off  
EMPTY  
EMPTY  
EMPTY  
EMPTY  
EMPTY  
EMPTY  
EMPTY  
More Mail Settings  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Bosch Security Systems  
Digital Video Recorder 440/480 Series  
Menu default values | en  
89  
Table 9.2 Configuration menu default values  
Navigation  
Setting  
Default value  
Reset  
System  
Date/Time  
Date  
Time  
2010-01-01  
12:00:00 AM  
YYYY/MM/DD  
12 hour  
GMT+0  
Off  
N
N
N
N
N
N
N
Date Format  
Time Format  
Time Zone  
Daylight Savings  
Daylight Savings  
Jan 1st Sun 00  
Start  
Daylight Savings End Jan 1st Sun 00  
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
NTP  
NTP  
Off  
Time Server  
Public server  
Private Time Server 0.0.0.0  
Sync Interval  
Button  
1 day  
Off  
Beeper  
Input  
Off  
Motion  
Off  
System  
On  
Video Loss  
Level  
Password  
Off  
User  
ADMINISTRATOR  
Administrator  
000000  
Configuration  
Import Configuration  
Export Configuration  
Factory Defaults  
Update Firmware  
Quick Install  
Hard Disk  
Overwrite  
Disk Full Warning  
Event Partition  
All  
90%  
0% (no separate  
Y
Y
N
partition)  
Auto Delete  
Format  
IR Remote Control  
DVR ID  
Off  
All  
1
1
Off  
Y
Y
Y
Y
Y
System  
Auto User Logout  
Table 9.3 Search menu default values  
Navigation  
Search  
Setting  
Date  
Time  
Channel  
Start  
End  
Event Type  
Channel  
Start  
End  
Sensitivity  
Area  
Default value  
Current Date  
Current Time  
1
Start of Video  
Current Time  
All  
1
Start of Video  
Current Time  
5
Off  
Reset  
Date/Time  
Event  
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Smart  
Table 9.4 Archive menu default values  
Navigation  
Archive  
Setting  
Default value  
None  
None  
Reset  
Channel  
Start Time  
End Time  
Y
Y
Y
None  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
90 en | Technical specifications  
Digital Video Recorder 440/480 Series  
10  
Technical specifications  
10.1  
Electrical  
Voltage and Power  
External power adapter AC input  
External power adapter DC output  
DVR power input  
100-240 VAC; 50/60 Hz; 1.8 A  
12 VDC; 3 A  
12 VDC; 3 A; 145 BTU/h  
Lithium: CR2032, 3 V, 225 mAh  
Internal battery  
Video  
Inputs  
Outputs  
Composite video 1 Vpp, 75 ohm (RG54)  
Monitor A - VGA RGB  
Monitor B - 1 Vpp, 75 ohm (RG54), sync 0.3 V  
10%  
Video standard  
Resolution  
SVGA  
PAL/NTSC auto-detect or menu selectable  
SVGA 800 x 600 or 1024 x 768 or 1280 x 1024  
704 x 576 PAL - 720 x 480 NTSC  
AGC  
Automatic adjustment of gain for each video input  
Digital Zoom  
Compression  
2 times  
H.264  
Audio  
Input  
Output  
Sample rate  
Compression  
Mono RCA, 1 Vpp, 10k ohm  
Mono RCA, 1 Vpp, 10k ohm  
8 kHz per channel  
ADPCM  
Alarm Handling  
Inputs  
4 configurable NO/NC  
max input voltage 15 VDC  
Output  
1 relay outputs; configurable NO/NC max rated  
30 VAC - 24 VDC - 0.5 A continuous  
Control  
RS232  
Output signals according to EIA/TIA-232-F, max  
input voltage 25 V  
Conform RS485  
RS485  
max signal voltage -8 V - +12 V  
Connectors  
Video inputs  
Audio input  
Ethernet  
Monitors  
Audio output  
Alarm connectors  
4/8 BNC  
1 RCA (CINCH)  
RJ45, 10/100BaseT according to IEEE802.3  
BNC (1), VGA D-sub (1)  
1 RCA  
Screw terminal inputs, cable cross section  
AWG 26-16 (0.13-1.5 mm2)  
DB9 male  
RS232  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Bosch Security Systems  
   
Digital Video Recorder 440/480 Series  
Technical specifications | en  
91  
RS485  
USB  
Screw terminal output, cable cross section  
AWG 28-16 (0.08-1.5 mm2)  
Type A connector (2)  
USB 2.0 on front and rear for mouse and USB  
memory device  
Storage  
Hard Disks  
1 SATA hard drive  
Record Rate (IPS)  
PAL: 25 total, configurable per camera: 25, 12.5,  
6.25, 5, 2.5, 1  
NTSC: 30 total, configurable per camera: 30, 15,  
7.5, 5, 3, 1  
Record Resolution  
Record Quality  
4CIF: 704 x 576 PAL - 704 x 480 NTSC  
2CIF: 704 x 288 PAL - 704 x 240 NTSC  
CIF: 352 x 288 PAL - 352 x 240 NTSC  
Best  
High  
Normal  
Low  
Lowest  
Display Modes  
Monitor A  
Full, full sequence, quad, alarm call-up (live and  
playback)  
Monitor B  
Full, full sequence, alarm call-up (live)  
Recording Modes  
Linear, continuous  
10.1.1  
10.1.2  
Mechanical  
Dimensions (excluding cabling)  
225 x 325 x 60 mm14.8 x 15 x 2.5 in.  
(W x D x H)  
Weight  
DVR 440: 2.9 kg (6.39 lb)DVR 480: 3.0 kg (6.6 lb)  
Environmental  
Temperature  
Operating: 0 °C to +40 °C (+32 °F to +104 °F)  
Storage: -40 °C to +70 °C (-40° F to +158 °F)  
Relative humidity  
Operating: <93% non-condensing  
Storage: <95% non-condensing  
Bosch Security Systems  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
AM18-Q0605 | v2.0 | 2012.04  
   
92 en | Technical specifications  
Digital Video Recorder 440/480 Series  
10.1.3  
Electromagnetic and Safety  
EMC requirements  
USA  
FCC Part 15, Class B  
EU  
EMC directive2004/108/EC  
EN50130-4  
Immunity  
Emission  
Harmonics  
Voltage fluctuations  
Safety  
EN55022 Class B  
EN61000-3-2  
EN61000-3-3  
USA  
UL60950-1  
EU  
CE, EN60950-1  
CAN/CSA - C22.2 no. 60950-1  
C-Tick  
Canada  
Australia  
10.2  
USB memory sticks  
The following USB memory sticks have been tested on the DVR 400 Series for firmware  
update and video export. Other brands/types might also work but could give problems.  
Brand/type  
Capacity  
2 GB  
Apacer  
Corsair Flash Voyager  
Kingston DataTraveler II plus MIGO  
8 GB, 16 GB  
8 GB  
Table 10.1 Recommended USB memory sticks  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Bosch Security Systems  
   
Digital Video Recorder 440/480 Series  
| en  
93  
A
Appendix  
A.1  
Software licenses  
This product contains both software that is proprietary Bosch software licensed under the  
Bosch standard license terms, and software licensed on the basis of other licenses.  
A.1.1  
A.1.2  
Bosch software  
All Bosch software © Bosch Security Systems.Bosch software is licensed under the terms of  
the End User License Agreement (EULA) of Bosch Security Systems B.V. or Bosch Security  
Systems Inc, as available together with the physical carrier (CD or DVD). Any use is subject to  
agreement and compliance with such EULA, as applicable.  
Other licenses — copyright notices  
GPL v2 copyright notice: This product includes software licensed under the GNU GPLv2  
Copyright © 1989, 1991 Free Software Foundation, Inc. 51 Franklin Street, Fifth Floor,  
Boston, MA 02110-1301, USA.  
GPL v3 copyright notice: This product includes software licensed under the GNU GPL v3  
Copyright © 2007 Free Software Foundation, Inc. (http://fsf.org/)  
LGPL v2.1 copyright notice: This product includes software licensed under the GNU  
LGPL v2.1 Copyright © 1991, 1999 Free Software Foundation, Inc. 51 Franklin Street,  
Fifth Floor, Boston, MA 02110-1301 USA  
SSL Copyright notice: This product includes software developed by the OpenSSL Project  
for use in the OpenSSL Toolkit (http://www.openssl.org/)  
Copyright © 1998-2008 The OpenSSL Project. All rights reserved.  
CDDL Copyright notices: This product includes software licensed under the CDDL v1.0  
At the time of printing this manual, the following other licenses apply to the following  
software components included in the DVR 600 Series:  
Name software component  
License (*)  
uboot, linux kernel, smartmontools, busybox, nbsmtp, rp-pppoe, GNU GPL v2  
fdisk, kernel modules, findutil  
uclibc  
GNU LGPL v2.1  
GNU GPL v3  
OpenSSL  
dosfstools  
openssl  
cdrtools  
CDDL v1.0, GNU GPL v2  
(*) Full texts of the appropriate licenses are available at the links below and are also delivered  
together with the software on the physical carrier.  
Bosch is committed to comply with the relevant terms of any open source license included in  
enable any licensee of open source software to have access to the relevant source code or  
other information that such licensee may be entitled to under the terms of a relevant license.  
Any software that is licensed under an open source license, under the terms of which the  
licensee is entitled to obtain the program or its source code, can be obtained through the  
Bosch Security Systems  
Installation and Operation manual  
AM18-Q0605 | v2.0 | 2012.04  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
       
94 en |  
Digital Video Recorder 440/480 Series  
OSS web site, indicated below, for the relevant period as mentioned in the relevant open  
source license.  
The relevant open source software can be found at:  
To obtain the complete Corresponding Source Code in the physical medium such as CD-ROM  
by airmail, Bosch may charge for reasonable costs related to producing a physical carrier of  
open source software or source code. This offer is valid to anyone in receipt of this  
information.  
A.1.3  
Warranties and disclaimer of warranties  
Software provided under other licenses has specific disclaimers of warranties. These are  
repeated in the full license texts, and apply in full to the relevant software components.  
All software components provided under the other licenses are provided "as is" without any  
warranty of any kind, including but not limited to any implied warranty of merchantability or  
fitness for a particular purpose, unless stated otherwise in writing. Please see the full text of  
the relevant software licenses for further details.The Bosch standard product warranty only  
applies to the combination of hardware and software as delivered by Bosch. Without  
prejudice to any licensee's right to apply the provisions of a relevant software license, any  
modification of any software delivered with or as part of the product may render any warranty  
on the whole product or any parts thereof null and void, and Bosch is entitled to charge fees  
for any services in relation thereto.  
AM18-Q0605 | v2.0 | 2012.04  
Installation and Operation manual  
Bosch Security Systems  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
 
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  
Bosch Security Systems  
© Bosch Security Systems, 2012  
للتحميل from Www.Somanuals.com. All Manuals Search And للتحميل.  

Billion Electric Company شبكة التوجيه BiPAC 7401VGPX دليل المستخدم
Black Box وسائط التخزين المحمولة 10 100BASE TX to 100BASE FX Media Converter دليل المستخدم
Black Decker آلة المشروبات الساخنة JKC920 دليل المستخدم
Black Decker Saw 587384 00 دليل المستخدم
Blue Rhino الفحم الشواء PC2694 2S دليل المستخدم
Boss Audio Systems سيارة مكبر للصوت R2400D دليل المستخدم
Boston Acoustics Speaker MM226 دليل المستخدم
Cabletron Systems شبكة التوجيه CSX400 دليل المستخدم
Cecilware Coffeemaker CH100N دليل المستخدم
Chicago Electric قوة المطرقة 94882 دليل المستخدم